10″ Microfiltration Elements

10" Sanitary Microfiltration Elements

10338 Element

Synder Filtration's 10" sanitary microfiltration elements offer excellent performance for very large scale production operations.  These elements are ideal where 800KD to 0.2µ membrane pore sizes are required for spiral wound MF filtration that needs to meet USDA or other sanitary compliance standards.4 

MEMBRANE ELEMENTS

Membrane Model Polymer Approx. Molecular Weight Cutoff
FR PVDF  800 KD 
V0.1 PVDF  0.1μ
V0.2  PVDF  0.2μ
Size Membrane Area 
(sq. ft)
Dimensions
(OD, L, P.W.T ID, Weight) 
Recommended Cross Flow Rate
10338 655 10.3", 38", 1.138", 55lb 224 GPM (50.9 m3/h)

*These is our most common model, contact us for information on custom models 
**These specifications are for elements with our standard 31mil spacer.  For complete product specifications for all models see our UF/MF Sanitary Specification Sheet.

 

 
RECOMMENDED OPERATING PARAMETERS 

Parameter Specification
Maximum Inlet Pressure  116 PSI (8.0 Bar)
Minimum Outlet Pressure 10 PSI (0.7 Bar)
Maximum Pressure Differential  18 PSI (1.2 Bar)
Maximum Permeate Back Pressure  5 PSI (0.3 Bar)
Maximum Operating/CIP Temperature   131° F (55° C)**/
122° F (50° C)**
 pH Range 
(Operating @ 55°C/ CIP @ 50°C Max)
 2-10/1.8-11**
 Maximum Chlorine 
(in DF Water or Product) 
 <0.1ppm
 Maximum Chlorine 
(During CIP @ pH 10.8-11.0 & 50°C)
 180ppm
 Maximum Free Peroxide 
(in Product During Operation)
 <3ppm
 Maximum Peroxide 
(as a Sanitizer @ 25°C Max, pH 6-7)
 0.1%

 *For expanded descriptions, please see our complete UF/MF Sanitary Specification Sheet.
**Synder Filtration offers a line of UF and MF elements specifically designed to operate under extreme temperature and pH conditions.  See the PHT spec sheet for more information.

This information is believed to be accurate and reliable, but is not to be construed as implying any warranty or guarantee of performance.  We assume no responsibility, obligation or liability for results obtained or damages incurred through the application of the information contained herein.  Refer to Standard Warranty documentation for additional information.