10" Sanitary Microfiltration Elements
Synder Filtration's 10" sanitary microfiltration elements offer excellent performance for very large scale production operations. These elements are ideal where 800KD to 0.2µ membrane pore sizes are required for spiral wound MF filtration that needs to meet USDA or other sanitary compliance standards.4
MEMBRANE ELEMENTS
| Membrane Model | Polymer | Approx. Molecular Weight Cutoff |
| FR | PVDF | 800 KD |
| V0.1 | PVDF | 0.1μ |
| V0.2 | PVDF | 0.2μ |
| Size | Membrane Area (sq. ft) |
Dimensions (OD, L, P.W.T ID, Weight) |
Recommended Cross Flow Rate |
| 10338 | 655 | 10.3", 38", 1.138", 55lb | 224 GPM (50.9 m3/h) |
*These is our most common model, contact us for information on custom models
**These specifications are for elements with our standard 31mil spacer. For complete product specifications for all models see our UF/MF Sanitary Specification Sheet.
RECOMMENDED OPERATING PARAMETERS
| Parameter | Specification |
| Maximum Inlet Pressure | 116 PSI (8.0 Bar) |
| Minimum Outlet Pressure | 10 PSI (0.7 Bar) |
| Maximum Pressure Differential | 18 PSI (1.2 Bar) |
| Maximum Permeate Back Pressure | 5 PSI (0.3 Bar) |
| Maximum Operating/CIP Temperature | 131° F (55° C)**/ 122° F (50° C)** |
| pH Range (Operating @ 55°C/ CIP @ 50°C Max) |
2-10/1.8-11** |
| Maximum Chlorine (in DF Water or Product) |
<0.1ppm |
| Maximum Chlorine (During CIP @ pH 10.8-11.0 & 50°C) |
180ppm |
| Maximum Free Peroxide (in Product During Operation) |
<3ppm |
| Maximum Peroxide (as a Sanitizer @ 25°C Max, pH 6-7) |
0.1% |
*For expanded descriptions, please see our complete UF/MF Sanitary Specification Sheet.
**Synder Filtration offers a line of UF and MF elements specifically designed to operate under extreme temperature and pH conditions. See the PHT spec sheet for more information.
This information is believed to be accurate and reliable, but is not to be construed as implying any warranty or guarantee of performance. We assume no responsibility, obligation or liability for results obtained or damages incurred through the application of the information contained herein. Refer to Standard Warranty documentation for additional information.