4″ Reverse Osmosis Elements

RO-SYN2-4040 Element

4040 Element 

The SYN-2-membrane is ideal where high salt rejection is a necessity and is the standard for most water purification processes.  This membrane is preferred when feedwater TDS exceeds 3000ppm and typically operates between 150 and 200 PSI.  In addition, Synder's UF and NF membranes and systems offer excellent pretreatment for a wide variety of applications.  

PERFORMANCE TESTING

  Model Active Membrane Area
 sq. ft (sq. m)
Average/Minimum Salt Rejection (%) Average Permeate Flow
GPD (m3/day)
RO-SYN2-4040 85 (7.9) 99.5/98.5 2,400 (9.0)

*Peformance based on following test conditions: 2,000 ppm NaCL, 225.0 psi, 25°C, 15% recovery, pH 8.0, 30 minutes operation
* Permeate flow is clean water flux at standard conditions above. Not applicable for all feedwater conditions. Individual element's permeate flow may vary +/- 15%.




PHYSICAL PROPERTIES

Membrane Length
in (mm)
Outer Diameter
in (mm) 
Permeate Tube OD
in (mm) 
Feed Spacer Dry Weight
lb (kg) 
TFC 40 (1,016) 4 (101) 0.75 (19.1) 31mil 15 (7)


RECOMMENDED OPERATING PARAMETERS 

Parameter Specification
Recommended Operating Pressure 100-300 PSI (7-21 Bar)
Maximum Inlet Pressure 600 PSI (41 Bar)
Recommended Operating Temperature 35-113ºF (2-45ºC)
Feed pH Range 2-11 continuous
Chlorine Tolerance <0.1 ppm
Maximum Feed Flow 20 GPM (4.5 m3/hr)
Minimum Brine Flow/Permeate Flow Ratio 5:1
Maximum SDI (15 minutes) 5.0
Maximum Turbidity 1 NTU

RO-SYN4-4040 Element

4040 Element

The SYN-4 membrane offers excellent performance for feed streams with relatively low TDS (3,000 ppm), while operating at very low pressures.  Typically requiring a feed pressure of 100 - 150 PSI, the SYN-4 boasts very high flux rates while still averages a 99.0% salt rejection.  Combined with reduced operating costs, the SYN-4 is a cost effective option for reverse osmosis water treatment.  

PERFORMANCE TESTING

  Model Active Membrane Area
 sq. ft (sq. m)
Average/Minimum Salt Rejection (%) Average Permeate Flow 
GPD (m3/day)
RO-SYN4-4040 85 (7.9) 99.0/98.0 3,350 (12.0)

*Peformance based on following test conditions: 2,000 ppm NaCL, 225.0 psi, 25°C, 15% recovery, pH 8.0, 30 minutes operation
* Permeate flow is clean water flux at standard conditions above. Not applicable for all feedwater conditions. Individual element's permeate flow may vary +/- 15%.


PHYSICAL PROPERTIES

Membrane Length 
in (mm)
Outer Diameter
in (mm) 
Permeate Tube OD
in (mm) 
Feed Spacer Dry Weight
lb (kg) 
TFC 40 (1,016) 4 (101) 0.75 (19.1) 31mil 15 (7)

RECOMMENDED OPERATING PARAMETERS 

Parameter Specification
Recommended Operating Pressure 40-300 PSI (3-21 Bar)
Maximum Inlet Pressure 600 PSI (41 Bar)
Recommended Operating Temperature 35-113ºF (2-45ºC)
Feed pH Range 2-11 continuous
Chlorine Tolerance <0.1 ppm
Maximum Feed Flow 20 GPM (4.5 m3/hr)
Minimum Brine Flow/Permeate Flow Ratio 5:1
Maximum SDI (15 minutes) 5.0
Maximum Turbidity 1 NTU