Short Term Storage

-for 6 months or less-

Immediately following the final CIP flush, the system should be filled with 1% Sodium Metabisulfite (MBS) solution with a pH of 4.0 to 5.0.

Every 7-10 days the following procedure should be performed:

  1. Drain MBS solution from the system.
  2. Flush system to the drain.
  3. Run a caustic wash (pH 10.8-11.0, 120°F-122°F, 15-20 minutes)
  4. Flush system to drain.
  5. Recharge the system with a fresh batch of MBS solution.

For further assistance, call our Technical Support Department at 1 (800) 279-6337, or email support@synderfiltration.com.

Synder Filtration believes the information and date herein to be accurate. However, said information is offered in good faith, but without guarantee since the conditions and methods used are beyond our control. Synder Filtration assumes no liability as to the application of the previously mentioned data.