TechCELL Installation

Installation of the TechCELL requires an electrical supply, mechanical support, and an anolyte recirculation system. AB TechCELL systems require 2 smaller anolyte systems (one for each type of cell).

  1. Electrical Supply: The units are connected to a DC bus bar with a cable lead (separable with quick disconnects) via a copper setscrew lug that typically accepts up to five cable leads (100 amp rated minimum).
  2. Mechanical Support: The typical installation uses 1-5/8" series strut channel and standard clamps. To mount the channel:

    With the backside of the channel approximately 3/4" off the paint tank inside wall, the bottom channel is mounted immediately above the tank rim. The top channel is then mounted at least 6" in the center above the bottom channel. These channels both require vertical support at no more than 5' center to center down the entire span of channel.


Click here for larger image

  1. Anolyte Circulation System(s): The anolyte supply is pumped through the supply manifold to where the individual cells are mounted. The solution is then directed from the supply manifold to each individual cell at a rate of approximately .6 GPM through 3/8" PVC tubing. The anolyte is removed from the cell through an overflow nozzle and flows to the return manifold via 1/2" PVC tubing. On cells longer than 114", use 3/4" return tubing.

 

TechCELL Piping Configuration
Click to enlarge image